When Is the Best Time for a Thermal Imaging Survey?

On a cold, dry, still day between roughly November and March, early in the morning or after dark, with the heating on for a few hours first. The camera needs a big difference between inside and outside, commonly at least 10°C, and no sun on the walls beforehand.

Why the weather matters

A thermal camera reads the temperature of surfaces. Heat loss only shows up when the inside of the house is much warmer than the outside, because that's what drives heat through the gaps. On a mild day, a house with no loft insulation and a house with plenty can look almost the same.

Building thermography guidance commonly asks for at least a 10°C difference between inside and out, held for several hours before the survey. In West Yorkshire that's easy to get on a winter morning and hard to get in June.

The conditions we look for

  • <b>A big temperature difference.</b> Commonly at least 10°C between inside and outside.
  • <b>Heating on beforehand.</b> At its normal setting for at least a couple of hours, ideally longer, so the walls have warmed through.
  • <b>No sun on the walls.</b> Sunshine warms brick and render for hours afterwards and hides what's underneath, so early morning, after dark or a dull day is best.
  • <b>Dry walls.</b> Wet surfaces cool as they dry, which can look like heat loss or hide it. Rain on the day stops the outside scan.
  • <b>Not much wind.</b> Wind cools outside surfaces unevenly and blurs the picture.
  • <b>Steady weather.</b> A sudden warm spell or a hard frost arriving mid-survey makes the readings harder to compare.

The best months and times of day

WhenOutside heat-loss scanInside checks
November to MarchBest. Cold mornings and evenings give the clearest picturesYes
October and AprilPossible on cold, still mornings or after darkYes
May to SeptemberUsually not. The house and the air are too close in temperatureDamp, leaks and underfloor heating, yes

What can be checked any time of year

Plenty of the work doesn't depend on the season. A damp survey works all year, because moisture readings don't need cold weather. Leak detection works whenever hot water is running through the pipes, since the pipes make their own temperature difference. An underfloor heating check just needs the heating switched on.

Solar panels are the opposite of a heat check: they need strong sunshine, so the panels are working hard and any faulty cells stand out as hot spots.

Getting your house ready

  • Put the heating on at its normal setting for at least a couple of hours before we arrive.
  • Keep windows and outside doors shut from the evening before if you can.
  • Pull furniture a little away from outside walls in the rooms you're worried about.
  • Make sure we can get to the loft hatch, and let us know about any rooms you'd like us to look at closely.

Questions

Quick Answers

Can you do a thermal survey in summer?

Not for heat loss through the walls and roof, because inside and outside are too close in temperature. Damp surveys, leak detection and underfloor heating checks work all year.

Does it have to be done at night?

No. Early morning or a dull, overcast day works well. What matters is that the sun hasn't been on the walls for a few hours.

What if it rains on the day?

Rain stops the outside scan, because wet walls cool as they dry and give a false picture. The inside part can usually still go ahead.